10 Notes on wiring
10.1 Alarm centre
Terminal connector strip for tamper and alarm zones.
COM A/T: Connections for detector tampering
CCT 1…8: Connections for alarm zones 1–8
Terminal connector strip for 12V DC power supply of
external equipment (e.g., detectors)
AUX: +12V permanent voltage for detectors
0V: 0V ground
Terminal connector strip for loudspeaker, progr. outputs and
siren tampering.
TR: Sabotage inputs
+ / LS: Contact for optional 16 Ohm loudspeaker
OP3: Contact for Open Collector Transistor output
(e.g. as trigger signal of dialler)
RELAY
OUTPUTS:Connections for 2 relays NC/NO
Terminal strip for control units
12V: 12V+ permanent voltage
0V: 0V ground
Data: Databus
Clock: Databus
5 Connection for PC data cable