Abus FUMK50020B Service Manual Page 22

  • Download
  • Add to my manuals
  • Print
  • Page
    / 140
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 21
- 22 -
Range
The range is dependent on environmental factors. Check whether the detector is
communicating properly with the alarm control panel prior to assembly.
When assembling the detector:
do not assemble it on or near metal surfaces.
keep it at least 1 m from gas, water or power lines.
do not assemble it near electronic equipment such computers, photocopiers or
other transmitters and interferences.
Installation location
The optimal installation position for your wireless opening detector is the top corner
of your window/door frame or leaf. Make sure that you install the detector on an
even surface so that the tamper switch (anti-removal wall contact) operates reliably.
The wireless opening detector can be installed on either the window frame or the
leaf of the door.
Select the installation position best suited to the individual location:
Rabbet
depth
Window/door
frame
Window/door leaf
7 mm magnet
bracket plate
< 19 mm
magnet/detector
magnet/detector
optional
> 19 mm
magnet
detector
compulsory
Page view 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 ... 139 140

Comments to this Manuals

No comments